1.
Chinese Journal of cardiovascular Rehabilitation Medicine ; (6): 486-490, 2019.
Article in Chinese | WPRIM | ID: wpr-753162

ABSTRACT

To explore influence of ultrasound‐guided lauromacrogol foam sclerotherapy on peripheral blood levels of counting of endothelial cells (CEC) , endothelin (ET)‐1 and nitric oxide (NO) in patients with sa‐phenous vein varicosis .Methods : A total of 90 patients with saphenous vein varicosis were randomly and equally di‐vided into lauromacrogol group (received ultrasound‐guided lauromacrogol foam sclerotherapy ) and routine treat‐ment group (received routine stripping ).Peripheral blood levels of CEC , ET‐1 and NO were observed and com‐pared between two groups before and after surgery , and therapeutic effect and incidence of complications were eval‐uated.Results : Compared with routine treatment group , there were significant reductions in surgery time [ (81. 79 ± 16.88) min vs .(40.55 ± 10. 19) min] , hospitalization time [(3.94 ± 1.36) d vs.(2. 17 ± 1.31) d] and hospital‐ization fee [ (7640. 15 ± 1025.11) RMB vs.(3998.89 ± 910. 67 ) RMB ] in lauromacrogol group , P= 0.001 all. Compared with routine treatment group after surgery , there were significant reductions in incidence rate of total complications (17.78% vs .4. 44%) , percentage of patient's condition class IV (17. 78% vs.4.44%) , peripheral blood levels of CEC [ (5562. 48 ± 1194. 73)/L vs.(4655.87 ± 1209. 88)/L] and ET‐1 [ (70. 32 ± 10.30) ng/L vs. (62.95 ± 13.78) ng/L] , and significant rise in percentage of patient’ s condition class I (6.67% vs.25. 00%) and peripheral blood NO level [(1.27 ± 0.42) μmol/L vs.(1. 59 ± 0.51) μmol/L] in lauromacrogol group , P<0. 05 or<0. 01. Conclusion : Ultrasound‐ guided lauromacrogol foam sclerotherapy can significantly increase therapeutic effect , improve vascular endothelial function in patients with saphenous vein varicosis .And its complications are few .

2.
Chinese Journal of Radiology ; (12)1999.
Article in Chinese | WPRIM | ID: wpr-680107

ABSTRACT

Objective To evaluate the efficacy and feasibility of the coil-and-glue method for the reduction of lung volume in rabbit emphysema model.Methods Sixteen rabbits of emphysema model were divided into the occlusion group(n=10),in which both anterior bronchi were occluded using the coil-and- glue method,and the control group(n=6).The maximal static pressure of airway(P_(max)),peak expiratory flow(PEF),end-expiratory volume(EEV)and pressure of oxygen(PO_2)were measured at ante- emphysema,post-emphysema,1 week and 4 week after occlusion respectively.The expectoration(or migration)of coil and collapse of lung were also investigated.Results P_(max)was(20.0?1.3)and(17.1? 1.4)cm H_2O(1 cm H_2O=0.098 kPa)in the occlusion group at ante-emphysema and post-emphysema respectively.P_(max)was(19.2?1.4)cm H_2O in the occlusion group in the 1 week after the occlusion,while (17.1?1.5)cm H_2O in the control group(F=6.68,P

SELECTION OF CITATIONS
SEARCH DETAIL